Assertion : Mono ammonium phosphate is only a type of DCP which is used in use class A fire Reason : Because it could knock of the flames part of the Powder would melt and form a crust the burning material excluding Oxygen and managing to extinguish the glow within the burning material (A) Both Assertion and Reason are true and Reason is the correct explanation of Assertion. (B) Both Assertion and Reason are true but Reason is not the correct explanation of Assertion. (C) Assertion is true but Reason is false. (D) Assertion is false but Reason is true.
Asked in GPSC Assistant Director/Regional Fire Officer, Class-1 under the Directorate of Gujarat State Fire Prevention Service 2023
Show answer
Answer: A. Both Assertion and Reason are true and Reason is the correct explanation of Assertion.
More GPSC Prelims previous year questions questions
- Statement 1 : Light timber frame structures are protected from fire by linings of non-combustible materials. Statement 2 : Fire exposed heavy timber members tend to deform much less than unprotected steel members. (A) Both the statements 1 and 2 are true (B) Statement 1 is true and statement 2 is false (C) Statement 1 is false and statement 2 is true (D) Both the statements 1 and 2 are false
- What should you do if a fire becomes too large to control with a portable extinguisher? (A) Continue using the extinguisher until it’s empty. (B) Evacuate the area and call the fire department. (C) Open windows and doors to let in more oxygen. (D) Use a fire blanket to smother the flames.
- Which of the following is an example of a primary sensing element used in temperature measurement in industrial instrumentation? (A) Pressure transducer (B) Flowmeter (C) Thermocouple (D) pH electrode
- Assertion : The use of fire-resistant materials in building construction is a critical aspect of structural fire protection. Reason : Fire-resistant materials can delay the spread of fires and provide occupants with more time to evacuate a burning building. (A) Both Assertion and Reason are true and Reason is the correct explanation of Assertion. (B) Both Assertion and Reason are true but Reason is not the correct explanation of Assertion. (C) Assertion is true but Reason is false. (D) Assertion is false but Reason is true.
- The investigation of electrical fires and failures is a responsibility which should be undertaken by (A) Electrical Companies and contractors (B) Stakeholders and owners (C) Maintenance supervisors and engineers (D) Manufactures and distributors
- In fire safety engineering, what does the term “LFL” (Lower Flammable Limit) refer to? (A) The minimum temperature required for a fire to ignite (B) The maximum concentration of fuel in the air that will support combustion (C) The ignition source responsible for starting a fire (D) The extinguishing agent.
- Assertion : Reciprocating pump is not used in most of the fire Tenders. Reason : As its shut off head is zero. (A) Both Assertion and Reason are true and Reason is the correct explanation of Assertion. (B) Both Assertion and Reason are true but Reason is not the correct explanation of Assertion. (C) Assertion is true but Reason is false. (D) Assertion is false but Reason is true.
- Read the following statements: i. Fire service hydraulics is the study of how water flows through fire hoses and nozzles. ii. Fire service hydraulics is important for firefighters to understand to operate firefighting equipment effectively. iii. Fire service hydraulics is also important for firefighters to understand to predict how water will flow through a building during a fire. iv. Fire service hydraulics is a complex subject, but it is essential for firefighters to have a basic understanding of it Which of the following is/are true? (A) i , iv (B) i, ii and iii (C) i, ii, iii, iv (D) ii, iii