Statement 1 : Foam concentrate wetting agents for increasing penetrating ability of Water. Statement 2 : Class A Foam concentrate primarily for class A Fire.
Asked in GPSC Assistant Director/Regional Fire Officer, Class-1 under the Directorate of Gujarat State Fire Prevention Service 2023
Show answer
Answer: A. Both the statements 1 and 2 are true
More GPSC Prelims previous year questions questions
- Assertion : As per the investigations, the electrical fires are the result of defects or deficiencies in the protective system. Reason : Electrical short circuits are not the causes of fires. They are stages in the failure processes which sometimes, but not always, end in fires. (A) Both Assertion and Reason are true and Reason is the correct explanation of Assertion. (B) Both Assertion and Reason are true but Reason is not the correct explanation of Assertion. (C) Assertion is true but Reason is false. (D) Assertion is false but Reason is true.
- Statement 1 : In arson investigations, the primary goal is to determine the cause of the fire. Statement 2 : Accelerants are substances that slow down the spread of a fire. (A) Both the statements 1 and 2 are true (B) Statement 1 is true and statement 2 is false (C) Statement 1 is false and statement 2 is true (D) Both the statements 1 and 2 are false
- Read the following options below: i. IS-4571: Specification for aluminum, extension ladders for fire brigade use ii. IS-2189: Selection, installation and maintenance of automatic fire detection and alarm system iii. IS-4989: Foam concentration for producing mechanical foam for firefighting iv. IS-901: Design of Sprinkler System (A) only i, ii and iii (B) both i and ii (C) only ii (D) both iii and iv
- A proper investigation by a coroner will always include analysis of the blood for the percent of carboxyhemoglobin contained in it. On what percentage above of the following, it is highly probable that the person was at least unconscious at the time the fire reached him. (A) 10% (B) 20% (C) 40% (D) 60%
- Which one of the following is not the necessary conditions for electrical fires? (A) Electrically powered equipment or lighting fixtures that depend on the suspected connection must be drawing current at the time of the fire (B) An overload or fault condition allowing excessive current to flow (C) Suitable combustibles present at the point of origin. (D) None of the above
- Match the following: a. IS 15105 b. IS 15683 c. IS 15325 d. NFPA 72 i. Water spray system ii. Automatic sprinkler system iii. Fire alarm and signalling code iv. Portable fire extinguishers (A) a – iii, b – ii, c – iv, d – i (B) a – ii, b – iv, c – i, d – iii (C) a – i, b – iv, c – iii, d – ii (D) a – iv, b – ii, c – i, d – iii
- The minimum effective discharge time of extinguishers with 1A rating shall be not less than (A) 6 sec (B) 7 sec (C) 8 sec (D) 9 sec
- i. Fire investigators are trained to determine the cause and origin of fires. ii. Fire investigators use a variety of techniques to collect evidence at fire scenes. iii. Fire investigators work closely with law enforcement officers to investigate arson fires. Which of the following is/are true? (A) i, iii, iv (B) ii, ii and iii (C) i, ii, iii, iv (D) ii, iii, iv