The input power to a 3-phase 4-pole 50 Hz induction motor is 125 kW. The motor runs at 5% slip. If the stator copper loss, stator iron loss and mechanical losses are 3 kW, 1.5 kW and 2 kW respectively, efficiency of the motor is

Asked in APPSC (Arunachal) Question Booklet (Set-A) of Paper I and Paper II 2026

  1. 90%
  2. 98%
  3. 95%
  4. 85%
Show answer

Answer: C. 95%