Universal Extinguisher is
Asked in GPSC Assistant Director/Regional Fire Officer, Class-1 under the Directorate of Gujarat State Fire Prevention Service 2023
Show answer
Answer: B. CO2 type
More GPSC Prelims previous year questions questions
- In an incendiary fire investigation, the source of ignition may be direct or time-delayed. In this regard, which one of the following is not a time-delayed ignition device?
- What is the pressure in pipe when measure by vertical water column manometer shows reading of 1.5 meter height from its center of pipe (Take g = 10 m/s2).
- Statement 1 : Alarm actuated by heat, smoke, flame-sensing devices, or the water flow in a sprinkler system conveyed to local alarm bells and/or the fire station. Statement 2 : Alarm boxes that automatically transmit a coded signal to the fire station to give the location of the alarm box.
- Match the following under electrical fire investigations List I List II a. Joule burns i. Electrocution b. Crocodile flash burn ii. Lightening c. Moist burn iii. Scalds d. Filigree burn iv. Electrical
- Match the following: a. Specification of no percolating fire hose b. Specification of hose coupling, nozzle, branch pipe c. Specification of fire hose maintenance d. Specification of underground fire hydrant sluice valve type i. IS 909-1992 ii. IS 903-1993 iii. IS 636-2018 iv. IS 14851-2018 (A) a - iii, b - ii, c - iv, d - i (B) a - ii, b - iv, c - i, d - iii (C) a - i, b - iv, c - iii, d - ii (D) a - iv, b - ii, c - i, d - iii
- Assertion : Floating roof tank is especially important for the storage of volatile liquids like gasoline and crude oil. Reason : The floating roof acts as a barrier between the stored liquid and the atmosphere, minimizing the evaporation of volatile compounds. (A) Both Assertion and Reason are true and Reason is the correct explanation of Assertion. (B) Both Assertion and Reason are true but Reason is not the correct explanation of Assertion. (C) Assertion is true but Reason is false. (D) Assertion is false but Reason is true.
- Statement 1 : The act contains provisions for penalties in case of violations, including imprisonment and fines. Statement 2 : The Petroleum Rules, 2002, were issued under the authority of the Petroleum Act, 1934. (A) Both the statements 1 and 2 are true (B) Statement 1 is true and statement 2 is false (C) Statement 1 is false and statement 2 is true (D) Both the statements 1 and 2 are false
- All static water tanks for fire fighting shall normally be located within ______ of the risk to be protected: (A) 60 meter (B) 100 meter (C) 120 meter (D) 150 meter