Which of the following statements accurately describes aspects of pressure distribution under a strip footing? (i) The pressure bulb under a strip footing develops longitudinally. (ii) The pressure bulb under a strip footing develops laterally. (iii) The contact pressure at the edges of a rigid footing on saturated clay is theoretically infinite.
Asked in GPSC Deputy Soil Survey Officer, Class-II 2024
Show answer
Answer: A. (ii) & (iii) only
More GPSC Prelims previous year questions questions
- In a detailed estimate, the provision for contingencies is, usually
- If the actual observed value of Standard Penetration resistance, N is greater 15 in a fine sand layer below water table, then the equivalent penetration resistance will be ?
- Match List-I (Field test) with List-II (Parameters measured) and select the correct answer List-I a. Plate load test b. Standard Penetration test c. Static Dutch Cone Penetration test d. Dynamic Penetration test List-II 1. Total and Frictional resistance 2. Load intensity and settlement values 3. Ncd values 4. SPT values
- Which is the weakest concrete?
- The value of demolished material is known as
- The primary function of geogrid is?
- Which one of the following characteristics is not measured by geophysical method of soil exploration?
- Consider the following statements: i. undisturbed samples may be obtained with the help of augers ii. auger drilling is most effective in clayey soils iii. hollow stem augers are sometimes used to drill holes in silty sand Which of these statements are correct?