Ques #:90 Which one of the following statements is incorrect is respect to shear strength of granular soils :- 1) It is affected largely by the initial void ratio. 2) It is not affected by the effective stresses. 3) The cohesion value of uncemented granular soil is approximately zero. 4) Undrained strength is insignificant except during the earthquake.
Asked in RPSC 23Feb 2016Question Paper for VicePrincipal/Superintendent ITI Screening Test 2012(Civil Engineering)VICE PRINCIPAL/SUPDT. ITI - 2012
Show answer
Answer: B. It is not affected by the effective stresses.
More RPSC Prelims previous year questions questions
- Ques # :92 Which one of the following pairs is not correctly matched in context of IS456 provisions for reinforced concrete :- 1) Footing Design - Punching shear generally considered. 2) Concrete Cover - Essential for durability. 3) Beams are mostly - without shear reinforcement. 4) Roof slab design may be - Without shear reinforcement.
- Ques # :93 Side face reinforcement is required when the depth of beam is :- 1) Greater than 750 mm 2) Greater then 1000 mm 3) Greater then 300 mm 4) Greater then 500 mm
- Ques # :94 For design of slabs, IS456 specifies effective span to overall depth ratios, this is to safeguard mainly :- 1) Strength Criterion 2) Deflection Criterion 3) Crack widths 4) Temperature stresses
- Ques # :95 Specify the percentage increase in load carrying capacity (specified in IS456) for a column having longitudinal reinforcement tied with spirals as compared to the allowable load for it with lateral ties :- 1) 10% 2) 20% 3) 25% 4) 5%
- Ques # :96 Which of the following types of losses of prestressing occurs only in pretensioning and not in post-tensioning case :- 1) Friction 2) Creep of concrete 3) Relaxation of stress in steel 4) Elastic shortening (deformation) of concrete
- Ques # :97 The effective length of the fillet weld is :- 1) 0.7 X total length 2) total length - √2 X weld size 3) total length - 2 X throat size 4) total length - 2 X weld size
- Ques # :98 For same load, unsupported length and end conditions a laced column as compared to a battened column :- 1) is stronger 2) is weaker 3) is equally strong 4) cannot be compared
- Ques # :99 Consider the following statements :- Bearing stiffeners are provided in a plate girder (a) to avoid local bending failure of flange (b) to prevent buckling of web (c) to strengthen the web (d) under uniformly distributed loads. Which of these statements are correct ? 1) (a) , (b) and (c) 2) (b) and (c) 3) (a) , (c) and (d) 4) (a) , (b) and (d)